Accesbio inc CareStart™ G6PD Biosensor

1 Keep the device at room temperature during the test.
2 Press the power button to turn on the meter. All symbols appear on the display for 1 second and then code number will appear on the display automatically.
3 Insert the test strip with the G6PD side facing up until it does not enter further anymore. A beep will sound. When the blood symbol flashes on the standby mode, preparation for the test is done.
4 Take a drop of blood using a lancet. Put the finger with the collected blood at the end of the test strip and completely fill the window of test strip.
The measurement result appear on the display and is automatically recorded in the memory. The result shows G6PD enzyme activity at 30℃

Specifications

Test Type Quantitative point-of-care test
Measurement Precise measurement of total G6PD activity
Specimen Whole blood
Specimen Volume 5 ㎕
Result Time 4 minutes
Package Size
Analyzer 1 ea/box and 25 strips/bottle
Package  Analyzer 1ea, 25 strips/bottle

Other Specifications

–  Internal sensor for temperature calibration
–  Internal memory storage up to 1,000 test results
–  Automatic blood loading

G6PD deficiency

G6PD deficiency is a genetic disorder, resulting in no or low G6PD activity. People with G6PD deficiency should not take primaquine, an antimalarial drug, and other drugs with high oxidative stress because it could cause serious side effects such as acute hemolysis. Now, more countries are implementing G6PD screening as a part of their newborn screening program.

Features & Benefits

–  World’s First G6PD Quantitative Test Giving the Result in 4 Minutes.
– 
CareStart™ G6PD Biosensor gives quantitative measurement of total G6PD enzyme activity in just 4 minutes, which is suitable for neonatal and adult screening purposes.

Testprocedure

  1. Keep the device at room temperature during the test.
  2. Press the power button to turn on the meter. All symbols appear on the display for 1 second and then code number will appear on the display automatically.
  3. Insert the test strip with the G6PD side facing up until it does not enter further anymore. A beep will sound. When the blood symbol flashes on the standby mode, preparation for the test is done.
  4. Take a drop of blood using a lancet. Put the finger with the collected blood at the end of the test strip and completely fill the window of test strip. The measurement result appear on the display and is automatically recorded in the memory. The result shows G6PD enzyme activity at 30℃ and expressed U/dl.

Packaging Information

If you are searching for a niche product and if you can’t find this product, please contact us! + 31 (0) 13 590 58 00

© 2019 Aksamedical.net

color
https://aksamedical.com/wp-content/themes/maple/
https://aksamedical.com/
#c1c1c1
style2
paged
Loading posts...
/var/www/vhosts/aksamedical.com/httpdocs/
#
on
none
loading
#
Sort Gallery
on
no
off
off
off

Call Now